5925-00-253-4255

20 Products

45-000-P10-H2.5AMP

CIRCUIT BREAKER

NSN, MFG P/N

5925002534255

NSN

5925-00-253-4255

View More Info

45-000-P10-H2.5AMP

CIRCUIT BREAKER

NSN, MFG P/N

5925002534255

NSN

5925-00-253-4255

MFG

OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

Description

ACTUATOR FUNCTION: RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY STYLE: 5A SINGLE POLE TYPE
BOSS HEIGHT: 0.125 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.937 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.570 INCHES NOMINAL
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.5 AMPERES AC AND 2.5 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 25.0 AC AND 25.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 UNTHREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.970 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC AND 24.0 DC SINGLE LOCATION
OVERALL LENGTH: 1.970 INCHES NOMINAL
OVERALL WIDTH: 0.730 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 QUICK DISCONNECT, MALE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 70.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 140.0 SINGLE LOCATION
UNTHREADED MOUNTING HOLE DIAMETER: 0.170 INCHES NOMINAL

7277-2-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002524227

NSN

5925-00-252-4227

View More Info

7277-2-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002524227

NSN

5925-00-252-4227

MFG

SENSATA TECHNOLOGIES INC

Description

ACTUATOR FUNCTION: TRIP-RESET
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 3.0 AMPERES AC AND 3.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 800.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING
NOMINAL THREAD SIZE: 0.438 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 120.0 AC AND 28.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UN
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 2.000 MINIMUM AT 200 PCT AND 35.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION

DAHT102

TIE HANDLE

NSN, MFG P/N

5925002525462

NSN

5925-00-252-5462

View More Info

DAHT102

TIE HANDLE

NSN, MFG P/N

5925002525462

NSN

5925-00-252-5462

MFG

GENERAL ELECTRIC CO

Q0430-40

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925002525930

NSN

5925-00-252-5930

View More Info

Q0430-40

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925002525930

NSN

5925-00-252-5930

MFG

SCHNEIDER ELECTRIC USA INC.

Description

CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 17.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 9.500 INCHES NOMINAL
CIRCUIT BREAKER TYPE AND QUANTITY: 40 SINGLE POLE
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 240.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 200.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 3.812 INCHES NOMINAL
OVERALL HEIGHT: 26.125 INCHES NOMINAL
OVERALL WIDTH: 12.125 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 6A RECTANGULAR, SURFACE MOUNTING
SYSTEM FOR WHICH DESIGNED: FOUR WIRE THREE PHASE

QO430L200

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925002525930

NSN

5925-00-252-5930

View More Info

QO430L200

CIRCUIT BREAKER BOX

NSN, MFG P/N

5925002525930

NSN

5925-00-252-5930

MFG

SCHNEIDER ELECTRIC USA INC DBA SCHNEIDER ELECTRIC

Description

CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT: 17.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 9.500 INCHES NOMINAL
CIRCUIT BREAKER TYPE AND QUANTITY: 40 SINGLE POLE
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS: 240.0
MAIN LINE MAXIMUM CURRENT RATING IN AMPS: 200.0
MATERIAL: STEEL
MOUNTING METHOD: UNTHREADED HOLE
OVERALL DEPTH: 3.812 INCHES NOMINAL
OVERALL HEIGHT: 26.125 INCHES NOMINAL
OVERALL WIDTH: 12.125 INCHES NOMINAL
STANDARD MOUNTING PATTERN DESIGNATOR: 7C 4 POINT-RECTANGULAR
STYLE DESIGNATOR: 6A RECTANGULAR, SURFACE MOUNTING
SYSTEM FOR WHICH DESIGNED: FOUR WIRE THREE PHASE

ETN9100TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528191

NSN

5925-00-252-8191

View More Info

ETN9100TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528191

NSN

5925-00-252-8191

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9100TU
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 4.375 INCHES NOMINAL
OVERALL LENGTH: 5.500 INCHES NOMINAL
OVERALL WIDTH: 3.000 INCHES NOMINAL
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 547.0 ALL LOCATIONS

ETN9101TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528192

NSN

5925-00-252-8192

View More Info

ETN9101TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528192

NSN

5925-00-252-8192

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 112.0 TO 137.0 DC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9101TU
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 3.000 INCHES NOMINAL
OVERALL LENGTH: 5.500 INCHES NOMINAL
OVERALL WIDTH: 4.375 INCHES NOMINAL
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 4 SCREW
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3600.000 NOMINAL AT 150 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 175.0 ALL LOCATIONS

ETN9135TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528203

NSN

5925-00-252-8203

View More Info

ETN9135TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528203

NSN

5925-00-252-8203

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9135TU
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 200.0 AMPERES DC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 6.000 INCHES NOMINAL
OVERALL LENGTH: 8.500 INCHES NOMINAL
OVERALL WIDTH: 3.750 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 550.0 ALL LOCATIONS

ETN9136TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528204

NSN

5925-00-252-8204

View More Info

ETN9136TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528204

NSN

5925-00-252-8204

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9136TU
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 225.0 AMPERES DC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 6.000 INCHES NOMINAL
OVERALL LENGTH: 8.500 INCHES NOMINAL
OVERALL WIDTH: 3.750 INCHES NOMINAL
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 551.0 ALL LOCATIONS

ETN9126TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528214

NSN

5925-00-252-8214

View More Info

ETN9126TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528214

NSN

5925-00-252-8214

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 35.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 3.594 INCHES NOMINAL
OVERALL LENGTH: 5.500 INCHES NOMINAL
OVERALL WIDTH: 4.500 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 TAB, SOLDER LUG
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 25.000 MINIMUM AT 500 PCT AND 40.000 MAXIMUM AT 500 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 135.0 ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER: 0.164 INCHES NOMINAL

ETN8424

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528216

NSN

5925-00-252-8216

View More Info

ETN8424

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528216

NSN

5925-00-252-8216

MFG

SPD ELECTRICAL SYSTEMS INC

Description

ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 3000.0 TO 3500.0 AC AND 3000.0 TO 3500.0 DC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN8424
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 250.0 AMPERES AC AND 250.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC AND 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 3.109 INCHES NOMINAL
OVERALL LENGTH: 8.469 INCHES NOMINAL
OVERALL WIDTH: 4.844 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 SCREW
THE MANUFACTURERS DATA:
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 3600.000 NOMINAL AT 150 PCT AND 120.000 MINIMUM AT 300 PCT AND 300.000 MAXIMUM AT 300 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 200.0 ALL LOCATIONS

ETN9185TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528218

NSN

5925-00-252-8218

View More Info

ETN9185TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528218

NSN

5925-00-252-8218

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9185TU
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 325.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 5.750 INCHES NOMINAL
OVERALL LENGTH: 8.500 INCHES NOMINAL
OVERALL WIDTH: 4.750 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 1400.0 ALL LOCATIONS

ETN9189TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528220

NSN

5925-00-252-8220

View More Info

ETN9189TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528220

NSN

5925-00-252-8220

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9189TU
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 500.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 5.750 INCHES NOMINAL
OVERALL LENGTH: 8.500 INCHES NOMINAL
OVERALL WIDTH: 4.750 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 1400.0 ALL LOCATIONS

ETN9191TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528222

NSN

5925-00-252-8222

View More Info

ETN9191TU

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002528222

NSN

5925-00-252-8222

MFG

SPD ELECTRICAL SYSTEMS INC

Description

CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: ETN9191TU
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 600.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
OVERALL HEIGHT: 5.750 INCHES NOMINAL
OVERALL LENGTH: 8.500 INCHES NOMINAL
OVERALL WIDTH: 4.750 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
THE MANUFACTURERS DATA:
TRIP RELEASE METHOD: MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 1400.0 ALL LOCATIONS

M13516/6-2

CIRCUIT BREAKER

NSN, MFG P/N

5925002530096

NSN

5925-00-253-0096

View More Info

M13516/6-2

CIRCUIT BREAKER

NSN, MFG P/N

5925002530096

NSN

5925-00-253-0096

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY STYLE: 14A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.780 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M13516/6BI-15
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH BUTTON
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 575.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.430 INCHES MAXIMUM
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-C-13516/6
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 28.0 DC SINGLE LOCATION
OVERALL LENGTH: 2.190 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: MANUAL
SPEC/STD CONTROLLING DATA:
SPECIFICATION/STANDARD DATA: 81349-M13516/6BI GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 2 TAB W/SCREW
TEST DATA DOCUMENT: 81349-MIL-C-13516 SPECIFICATION
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: THERMAL SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 138.0 SINGLE LOCATION

NB231100

CIRCUIT BREAKER

NSN, MFG P/N

5925002534241

NSN

5925-00-253-4241

View More Info

NB231100

CIRCUIT BREAKER

NSN, MFG P/N

5925002534241

NSN

5925-00-253-4241

MFG

CHALLENGER ELECTRICAL EQUIPMENT CORP

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 100.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 5000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 6 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 240.0 AC ALL LOCATIONS
OVERALL HEIGHT: 2.812 INCHES NOMINAL
OVERALL LENGTH: 4.375 INCHES NOMINAL
OVERALL WIDTH: 3.000 INCHES NOMINAL
POLE QUANTITY: 3
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 3 COMPRESSION AND 3 CLIP
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 42.000 MINIMUM AT 200 PCT AND 180.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 125.0 ALL LOCATIONS

27A10588-103-11

CIRCUIT BREAKER

NSN, MFG P/N

5925002535074

NSN

5925-00-253-5074

View More Info

27A10588-103-11

CIRCUIT BREAKER

NSN, MFG P/N

5925002535074

NSN

5925-00-253-5074

MFG

THE BOEING COMPANY DBA BOEING

2TC12-7 1/2

CIRCUIT BREAKER

NSN, MFG P/N

5925002535074

NSN

5925-00-253-5074

View More Info

2TC12-7 1/2

CIRCUIT BREAKER

NSN, MFG P/N

5925002535074

NSN

5925-00-253-5074

MFG

SENSATA TECHNOLOGIES INC

30-014-7

CIRCUIT BREAKER

NSN, MFG P/N

5925002535074

NSN

5925-00-253-5074

View More Info

30-014-7

CIRCUIT BREAKER

NSN, MFG P/N

5925002535074

NSN

5925-00-253-5074

MFG

BELL HELICOPTER TEXTRON INC.

AM17-40-32-54

CIRCUIT BREAKER

NSN, MFG P/N

5925002535137

NSN

5925-00-253-5137

View More Info

AM17-40-32-54

CIRCUIT BREAKER

NSN, MFG P/N

5925002535137

NSN

5925-00-253-5137

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 4A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.190 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.812 INCHES NOMINAL
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: EXPLOSION RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3000.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
MOUNTING SURFACE TO TERMINAL END DISTANCE: 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE: 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 32.0 DC SINGLE LOCATION
POLE QUANTITY: 1
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 18.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC: TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD: MAGNETIC-HYDRAULIC SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT: 150.0 SINGLE LOCATION