Featured Products

My Quote Request

No products added yet

5945-01-308-7463

20 Products

R7549-1

RELAY,REED

NSN, MFG P/N

5945013087463

NSN

5945-01-308-7463

View More Info

R7549-1

RELAY,REED

NSN, MFG P/N

5945013087463

NSN

5945-01-308-7463

MFG

ELEC-TROL INC

Description

(NON-CORE DATA) END ITEM SOURCE: 89536
COIL QUANTITY: 1
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: VIBRATION PROOF
III CUBIC MEASURE: 0.228 CUBIC INCHES
III END ITEM IDENTIFICATION: 6625-01-195-1067 NOISE ANALYZER SET
III FRAGILITY FACTOR: MODERATELY RUGGED
III PURPOSE FOR WHICH DESIGNED: GENERAL
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 500.0 MILLIAMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 120.0 AC AND 200.0 DC
MOUNTING FACILITY TYPE AND QUANTITY: 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 4.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 0.475 INCHES MAXIMUM
OVERALL LENGTH: 1.170 INCHES MAXIMUM
OVERALL WIDTH: 0.410 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 4 PIN ALL FUNCTIONS
WINDING DC RESISTANCE RATING: 600.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY: 1

120AP10SDC

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087466

NSN

5945-01-308-7466

View More Info

120AP10SDC

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087466

NSN

5945-01-308-7466

MFG

AMPERITE CO INC

Description

(NON-CORE DATA) END ITEM SOURCE: 90598
COIL QUANTITY: 1
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: DUSTPROOF AND FUNGUS PROOF AND SALT SPRAY RESISTANT
FREQUENCY IN HERTZ: 60.0 NOMINAL
III CUBIC MEASURE: 12.320 CUBIC INCHES
III END ITEM IDENTIFICATION: AIR COND UNIT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PURPOSE FOR WHICH DESIGNED: GENERAL
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 2.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 240.0 AC
MOUNTING FACILITY TYPE AND QUANTITY: 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 2.875 INCHES MAXIMUM
OVERALL LENGTH: 2.406 INCHES MAXIMUM
OVERALL WIDTH: 1.781 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
TIME DELAY: 0.06 SECONDS MAXIMUM FIXED RELEASE TIME
WINDING QUANTITY: 1

1603AS161

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087466

NSN

5945-01-308-7466

View More Info

1603AS161

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087466

NSN

5945-01-308-7466

MFG

NAVAL AIR SYSTEMS COMMAND

Description

(NON-CORE DATA) END ITEM SOURCE: 90598
COIL QUANTITY: 1
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: DUSTPROOF AND FUNGUS PROOF AND SALT SPRAY RESISTANT
FREQUENCY IN HERTZ: 60.0 NOMINAL
III CUBIC MEASURE: 12.320 CUBIC INCHES
III END ITEM IDENTIFICATION: AIR COND UNIT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PURPOSE FOR WHICH DESIGNED: GENERAL
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 2.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 240.0 AC
MOUNTING FACILITY TYPE AND QUANTITY: 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 2.875 INCHES MAXIMUM
OVERALL LENGTH: 2.406 INCHES MAXIMUM
OVERALL WIDTH: 1.781 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
TIME DELAY: 0.06 SECONDS MAXIMUM FIXED RELEASE TIME
WINDING QUANTITY: 1

CDA-38-70014

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087466

NSN

5945-01-308-7466

View More Info

CDA-38-70014

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087466

NSN

5945-01-308-7466

MFG

TYCO ELECTRONICS CORPORATION

Description

(NON-CORE DATA) END ITEM SOURCE: 90598
COIL QUANTITY: 1
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: DUSTPROOF AND FUNGUS PROOF AND SALT SPRAY RESISTANT
FREQUENCY IN HERTZ: 60.0 NOMINAL
III CUBIC MEASURE: 12.320 CUBIC INCHES
III END ITEM IDENTIFICATION: AIR COND UNIT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PURPOSE FOR WHICH DESIGNED: GENERAL
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 2.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 240.0 AC
MOUNTING FACILITY TYPE AND QUANTITY: 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 2.875 INCHES MAXIMUM
OVERALL LENGTH: 2.406 INCHES MAXIMUM
OVERALL WIDTH: 1.781 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
TIME DELAY: 0.06 SECONDS MAXIMUM FIXED RELEASE TIME
WINDING QUANTITY: 1

SLZ9693

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087817

NSN

5945-01-308-7817

View More Info

SLZ9693

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087817

NSN

5945-01-308-7817

MFG

AVIONICS SPECIALTIES INC.

0694-16

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087818

NSN

5945-01-308-7818

View More Info

0694-16

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087818

NSN

5945-01-308-7818

MFG

KOOLTRONIC INC.

65610-01808-101

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087861

NSN

5945-01-308-7861

View More Info

65610-01808-101

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087861

NSN

5945-01-308-7861

MFG

SIKORSKY AIRCRAFT CORPORATION

Description

(NON-CORE DATA) FSC APPLICATION DATA: TOW PANEL
DESIGN CONTROL REFERENCE: 65610-01808-101
III END ITEM IDENTIFICATION: MH-53E ACFT
MANUFACTURERS CODE: 78286
OVERALL HEIGHT: 1.000 INCHES NOMINAL
OVERALL LENGTH: 1.718 INCHES MAXIMUM
OVERALL WIDTH: 0.515 INCHES NOMINAL
THE MANUFACTURERS DATA:

3SBC2137A2

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087862

NSN

5945-01-308-7862

View More Info

3SBC2137A2

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087862

NSN

5945-01-308-7862

MFG

COMMUNICATIONS INSTRUMENTS INC DIV OF CII TECHNOLOGIES

Description

(NON-CORE DATA) FSC APPLICATION DATA: RELAY UNIT ASSEMBLY
III END ITEM IDENTIFICATION: MH-53E ACFT
MANUFACTURERS CODE: 78286
MFR SOURCE CONTROLLING REFERENCE: 61902-60227-101
OVERALL HEIGHT: 0.320 INCHES NOMINAL
OVERALL LENGTH: 0.610 INCHES NOMINAL
OVERALL WIDTH: 0.310 INCHES NOMINAL
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 8 WIRE LEAD ALL FUNCTIONS

61902-60227-101

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087862

NSN

5945-01-308-7862

View More Info

61902-60227-101

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013087862

NSN

5945-01-308-7862

MFG

SIKORSKY AIRCRAFT CORPORATION

Description

(NON-CORE DATA) FSC APPLICATION DATA: RELAY UNIT ASSEMBLY
III END ITEM IDENTIFICATION: MH-53E ACFT
MANUFACTURERS CODE: 78286
MFR SOURCE CONTROLLING REFERENCE: 61902-60227-101
OVERALL HEIGHT: 0.320 INCHES NOMINAL
OVERALL LENGTH: 0.610 INCHES NOMINAL
OVERALL WIDTH: 0.310 INCHES NOMINAL
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 8 WIRE LEAD ALL FUNCTIONS

274886

SOLENOID,ELECTRICAL

NSN, MFG P/N

5945013087931

NSN

5945-01-308-7931

View More Info

274886

SOLENOID,ELECTRICAL

NSN, MFG P/N

5945013087931

NSN

5945-01-308-7931

MFG

LISTER PETTER AMERICAS INCORPORATED

Description

ACTUATOR STROKE TYPE: PULL
BODY STYLE: 44 CYLINDRICAL FRAME
DUTY TYPE: CONTINUOUS
III END ITEM IDENTIFICATION: 2590-01-268-8229 KIT,AUXILARY POWER
INCLOSURE TYPE: FULLY INCLOSED
MAGNETIC COIL QUANTITY: 1
POWER TAKEOFF CONNECTION TYPE: PLAIN
TERMINAL LOCATION: BASE
TERMINAL TYPE AND QUANTITY: 3 TAB W/SCREW
VOLTAGE RATING IN VOLTS: 24.0 DC NOMINAL

9050JCK15V20

RELAY,SOLID STATE

NSN, MFG P/N

5945013087948

NSN

5945-01-308-7948

View More Info

9050JCK15V20

RELAY,SOLID STATE

NSN, MFG P/N

5945013087948

NSN

5945-01-308-7948

MFG

SCHNEIDER ELECTRIC USA INC.

Description

SPECIAL FEATURES: EIGHT PIN OCTAL TUBE PLUG; 2.340 IN. LG; 1.720 IN. W; 4.030 IN. HIGH; 120VAC; DELAY TIME 1.800 TO 180.000 SECONDS ON ENERGIZE

C20248-1

RELAY,SOLID STATE

NSN, MFG P/N

5945013087948

NSN

5945-01-308-7948

View More Info

C20248-1

RELAY,SOLID STATE

NSN, MFG P/N

5945013087948

NSN

5945-01-308-7948

MFG

LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN DIV LOCKHEED MARTIN AERONAUTICS COMPANY

Description

SPECIAL FEATURES: EIGHT PIN OCTAL TUBE PLUG; 2.340 IN. LG; 1.720 IN. W; 4.030 IN. HIGH; 120VAC; DELAY TIME 1.800 TO 180.000 SECONDS ON ENERGIZE

65911-01002-044

RELAY ASSEMBLY

NSN, MFG P/N

5945013088031

NSN

5945-01-308-8031

View More Info

65911-01002-044

RELAY ASSEMBLY

NSN, MFG P/N

5945013088031

NSN

5945-01-308-8031

MFG

SIKORSKY AIRCRAFT CORPORATION

Description

DESIGN CONTROL REFERENCE: 65911-01002-044
III END ITEM IDENTIFICATION: MH-53E ACFT
INDIVIDUAL RELAY QUANTITY: 6
MANUFACTURERS CODE: 78286
THE MANUFACTURERS DATA:

TPH1043111-1

RELAY ASSEMBLY

NSN, MFG P/N

5945013088032

NSN

5945-01-308-8032

View More Info

TPH1043111-1

RELAY ASSEMBLY

NSN, MFG P/N

5945013088032

NSN

5945-01-308-8032

MFG

NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE SYSTEMS

Description

DESIGN CONTROL REFERENCE: TPH1043111-1
III END ITEM IDENTIFICATION: ACFT F/A-18
MANUFACTURERS CODE: 26512
THE MANUFACTURERS DATA:

1001X

RELAY,HYBRID

NSN, MFG P/N

5945013088474

NSN

5945-01-308-8474

View More Info

1001X

RELAY,HYBRID

NSN, MFG P/N

5945013088474

NSN

5945-01-308-8474

MFG

TYCO ELECTRONICS CORPORATION DBA KILOVAC

Description

DESIGN CONTROL REFERENCE: 1001X
III END ITEM IDENTIFICATION: USED IN SHORE TIME PANEL ONBOARD 378 FT WHEC COAST GUARD VESSELS
MANUFACTURERS CODE: 18741
SPECIAL FEATURES: PHASE FAILURE DELAY NOM VOLTAGE 120 V,60 HZ;VOLTAGE DROP-OUT 75% - 100% OF NOM VOLTAGE;ADJUSTABLE;PICKUP TO DROPOUT DIFFERENTIAL 3% APPROX;OPERATING TEMP -20/+70 DEG C WITH DRIFT OF PORM 1%;TIME DELAY 0 TO 3.5 SEC;OUTPUT CONTACTS ONE SET NORMALLY
THE MANUFACTURERS DATA:
~1: OPENM;CONTACT RATING 10 AMP AT 28 VDC RESISTIVE;10 AMP AT 230 VAC RESISTIVE;SOLID STATE SENSOR W/RELAY OUTPUT IN A SEALED CAN

10705000

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013088574

NSN

5945-01-308-8574

View More Info

10705000

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013088574

NSN

5945-01-308-8574

MFG

BELL AND HOWELL INC MICRO DESIGN DIV

1603AS167

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013088585

NSN

5945-01-308-8585

View More Info

1603AS167

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013088585

NSN

5945-01-308-8585

MFG

NAVAL AIR SYSTEMS COMMAND

Description

(NON-CORE DATA) END ITEM SOURCE: 90598
COIL QUANTITY: 1
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: FUNGUS PROOF AND SALT SPRAY RESISTANT AND DUSTPROOF
FREQUENCY IN HERTZ: 50.0 MINIMUM AND 60.0 MAXIMUM
III CUBIC MEASURE: 12.998 CUBIC INCHES
III END ITEM IDENTIFICATION: AIR COND UNIT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PURPOSE FOR WHICH DESIGNED: GENERAL
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 5.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 240.0 AC
MOUNTING FACILITY TYPE AND QUANTITY: 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 440.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 2.350 INCHES MINIMUM AND 2.410 INCHES MAXIMUM
OVERALL LENGTH: 2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM
OVERALL WIDTH: 1.720 INCHES MINIMUM AND 1.780 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
TIME DELAY: 0.06 SECONDS NOMINAL FIXED OPERATE TIME 0.50 SECONDS NOMINAL FIXED RELEASE TIME
WINDING QUANTITY: 1

SLA-440-ASA

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013088585

NSN

5945-01-308-8585

View More Info

SLA-440-ASA

RELAY,ELECTROMAGNETIC

NSN, MFG P/N

5945013088585

NSN

5945-01-308-8585

MFG

AUTOMATIC TIMING & CONTROLS INC. DBA AUTOMATIC TIMING & CONTROLS DIV AUTOMATIC TIMING AND CONTROLS

Description

(NON-CORE DATA) END ITEM SOURCE: 90598
COIL QUANTITY: 1
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: FUNGUS PROOF AND SALT SPRAY RESISTANT AND DUSTPROOF
FREQUENCY IN HERTZ: 50.0 MINIMUM AND 60.0 MAXIMUM
III CUBIC MEASURE: 12.998 CUBIC INCHES
III END ITEM IDENTIFICATION: AIR COND UNIT
III FRAGILITY FACTOR: MODERATELY RUGGED
III PURPOSE FOR WHICH DESIGNED: GENERAL
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 5.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 240.0 AC
MOUNTING FACILITY TYPE AND QUANTITY: 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 440.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 2.350 INCHES MINIMUM AND 2.410 INCHES MAXIMUM
OVERALL LENGTH: 2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM
OVERALL WIDTH: 1.720 INCHES MINIMUM AND 1.780 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
TIME DELAY: 0.06 SECONDS NOMINAL FIXED OPERATE TIME 0.50 SECONDS NOMINAL FIXED RELEASE TIME
WINDING QUANTITY: 1

1 4260-101

SOLENOID,ELECTRICAL

NSN, MFG P/N

5945013089204

NSN

5945-01-308-9204

View More Info

1 4260-101

SOLENOID,ELECTRICAL

NSN, MFG P/N

5945013089204

NSN

5945-01-308-9204

MFG

ESE INC. DBA E S COMPONENTS COMPANY

0490-1204

RELAY,REED

NSN, MFG P/N

5945013089262

NSN

5945-01-308-9262

View More Info

0490-1204

RELAY,REED

NSN, MFG P/N

5945013089262

NSN

5945-01-308-9262

MFG

AGILENT TECHNOLOGIES INC. DBA NORTH AMERICAN CONTACT CENTER DIV AGILENT BUSINESS CENTER

Description

(NON-CORE DATA) END ITEM SOURCE: 28480
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
III END ITEM IDENTIFICATION: 6625-01-016-5966 GAIN PHASE METER; SPRUANCE CLASS DD, LOS ANGELES CLASS SSN (688), KIDD CLASS DDG, VIRGINIA CLASS CGN (41), SEAWOLF CLASS SSN, TICONDEROGA CLASS CG (47), GENERAL PURPOSE ELECTRONIC TEST EQUIPMENT GPETE
III FRAGILITY FACTOR: MODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 500.0 MILLIAMPERES AC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 117.0 AC
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
SPECIAL FEATURES: WEAPON SYSTEM ESSENTIAL
WINDING DC RESISTANCE RATING: 966.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY: 1