Featured Products

My Quote Request

No products added yet

6525-01-011-9428

20 Products

X-14

FILM,RADIOGRAPHIC

NSN, MFG P/N

6525010119428

NSN

6525-01-011-9428

View More Info

X-14

FILM,RADIOGRAPHIC

NSN, MFG P/N

6525010119428

NSN

6525-01-011-9428

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 100
(NON-CORE DATA) UNIT PACKAGE TYPE: BOX
BASE COLOR: BLACK OR BLUE
BASE MATERIAL: PLASTIC
BASE MATERIAL THICKNESS: 0.007 INCHES NOMINAL
CONTRAST RATING: 2.3 TO 2.8
CORNER CUT TYPE: ROUND
EMULSION SENSITIVITY: BLUE
EMULSION SPEED RANGE: 70.0 TO 100.0 RECIPROCAL ERGS PER SQ CM
FILM EXPOSURE QUANTITY: 1
GRANULE SIZE: ANY ACCEPTABLE
LENGTH: 1.000 FEET NOMINAL
SENSITIZED COATING LOCATION: BOTH SIDES
WIDTH: 5.000 INCHES NOMINAL

457838

ROLLER ASSEMBLY,PRO

NSN, MFG P/N

6525010068659

NSN

6525-01-006-8659

View More Info

457838

ROLLER ASSEMBLY,PRO

NSN, MFG P/N

6525010068659

NSN

6525-01-006-8659

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

DESIGN CONTROL REFERENCE: 457838
GENERAL CHARACTERISTICS ITEM DESCRIPTION: UPPER DETECTOR,FIBER ROLLER 18.500 IN. LG,1.000 IN. DIA,0.250 IN. DIA CRES SHAFT,FIRST END 0.938 IN. LG W/0.062 IN. ID @DRILLED HOLE 0.438 IN. FROM END,SECOND END 0.312 IN. LG
III PART NAME ASSIGNED BY CONTROLLING AGENCY: ROLLER ASSEMBLY PROCESSING UNIT RADIOGRAPHIC FILM UPPER DETECTOR
III UNIT OF ISSUE CUBE: 0.013 CUBIC FEET
MANUFACTURERS CODE: 19139
THE MANUFACTURERS DATA:

457839

ROLLER ASSEMBLY,PRO

NSN, MFG P/N

6525010068660

NSN

6525-01-006-8660

View More Info

457839

ROLLER ASSEMBLY,PRO

NSN, MFG P/N

6525010068660

NSN

6525-01-006-8660

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

DESIGN CONTROL REFERENCE: 473428
GENERAL CHARACTERISTICS ITEM DESCRIPTION: LOWER DETECTOR,RUBBER ROLLER,18.500 IN. LG,1.000 IN. DIA,0.250 IN. DIA CRES SHAFT,FIRST END 0.938 IN. LG W/0.062 IN. ID DRILLED HOLE 0.438 IN. FROM END,SECOND END 0.312 IN. LG
III PART NAME ASSIGNED BY CONTROLLING AGENCY: ROLLER ASSEMBLY PROCESSING UNIT RADOGRAPHIC FILM
III UNIT OF ISSUE CUBE: 0.013 CUBIC FEET
MANUFACTURERS CODE: 19139
THE MANUFACTURERS DATA:

473428

ROLLER ASSEMBLY,PRO

NSN, MFG P/N

6525010068660

NSN

6525-01-006-8660

View More Info

473428

ROLLER ASSEMBLY,PRO

NSN, MFG P/N

6525010068660

NSN

6525-01-006-8660

MFG

EASTMAN KODAK COMPANY DBA KODAK

Description

DESIGN CONTROL REFERENCE: 473428
GENERAL CHARACTERISTICS ITEM DESCRIPTION: LOWER DETECTOR,RUBBER ROLLER,18.500 IN. LG,1.000 IN. DIA,0.250 IN. DIA CRES SHAFT,FIRST END 0.938 IN. LG W/0.062 IN. ID DRILLED HOLE 0.438 IN. FROM END,SECOND END 0.312 IN. LG
III PART NAME ASSIGNED BY CONTROLLING AGENCY: ROLLER ASSEMBLY PROCESSING UNIT RADOGRAPHIC FILM
III UNIT OF ISSUE CUBE: 0.013 CUBIC FEET
MANUFACTURERS CODE: 19139
THE MANUFACTURERS DATA:

A0302C1000

X-RAY APPARATUS,DENTAL

NSN, MFG P/N

6525010076058

NSN

6525-01-007-6058

View More Info

A0302C1000

X-RAY APPARATUS,DENTAL

NSN, MFG P/N

6525010076058

NSN

6525-01-007-6058

MFG

GENERAL ELECTRIC CO MEDICAL SYSTEMS DIV

Description

ELECTRIC POWER RATING: 2100.0 WATTS NOMINAL
FREQUENCY IN HERTZ: 50.0 OR 60.0
III PART NAME ASSIGNED BY CONTROLLING AGENCY: X-RAY APPARATUS DENTAL WALL MOUNTED: 15MA 90PKV 100/130V 50/60HZ
MOUNTING TYPE: WALL
PHASE: SINGLE
SPECIAL FEATURES: SINGLE CONTROL CAPABLE OF OPERATING MORE THAN ONE X-RAY TUBEHEAD; FOR INTERCONNECTING CABLE ORDER 6145-00-889-1146; TIMER WITH RANGE OF 3/60 SECOND AND A DEADMAN PUSHBUTTON SWITCH W/COILED CORD 12 FEET (3.7 M) LONG
TRANSFORMER OUTPUT CAPACITY: 15.0 OUTPUT MA AT 90 KV PEAK
VOLTAGE IN VOLTS: 115.0

95 2720

FILM,RADIOGRAPHIC

NSN, MFG P/N

6525010088867

NSN

6525-01-008-8867

View More Info

95 2720

FILM,RADIOGRAPHIC

NSN, MFG P/N

6525010088867

NSN

6525-01-008-8867

MFG

DIPAK MFG CO

Description

(NON-CORE DATA) UNIT PACKAGE QUANTITY: 100
(NON-CORE DATA) UNIT PACKAGE TYPE: BOX
BASE COLOR: BLACK OR BLUE
BASE MATERIAL: PLASTIC, POLYESTER
BASE MATERIAL THICKNESS: ANY ACCEPTABLE
CONTRAST RATING: 2.3 TO 2.8
CORNER CUT TYPE: ROUND
EMULSION SENSITIVITY: BLUE
EMULSION SPEED RANGE: 70.0 TO 100.0 RECIPROCAL ERGS PER SQ CM
FILM EXPOSURE QUANTITY: 1
GRANULE SIZE: ANY ACCEPTABLE
LENGTH: 43.000 CENTIMETERS NOMINAL
SENSITIZED COATING LOCATION: BOTH SIDES
SPECIAL FEATURES: NON-INTERLEAVED
WIDTH: 35.000 CENTIMETERS NOMINAL

CRONEX DAYLIGHT SYSTEM

PROCESSING SET,RADI

NSN, MFG P/N

6525010108496

NSN

6525-01-010-8496

View More Info

CRONEX DAYLIGHT SYSTEM

PROCESSING SET,RADI

NSN, MFG P/N

6525010108496

NSN

6525-01-010-8496

MFG

DU PONT E I DE NEMOURS AND CO INC DUPONT PRINTING AND PUBLISHING

Description

GENERAL CHARACTERISTICS ITEM DESCRIPTION: 115 V AC; C/O DAYLIGHT FILM DISPENSERS FOR FILM SIZES 14 BY 17 IN.,14 BY 14 IN.,7 BY 17 IN.,11 BY 14 IN.,10 BY 12 IN.,9.5 BY 9.5 IN.,8 BY 10 IN; DAYLIGHT CASSETTES FOR THESE FILM SIZES; BATTERY POWERED FILM IDENTIFIER; DAYLIGHT CASSETTE UNLOADER; FREE
III PART NAME ASSIGNED BY CONTROLLING AGENCY: PROCESSING SET RADIOGRAPHIC FILM DAYLIGHT SYSTEM 115V 50 OR 60HZ
~1: STANDING; SHIELDED FROM FROM SCATTER RADIATION; ACCOMMODATES ALL SIZES CASSETTES; 28 IN. W,41 IN. H,21 IN. DEEP,DAYLIGHT TRANSPORT FEEDER ACCOMMODATING 30 FILMS ASSORTED SIZES AUTOMATED FEED OR TRANSPORT CASE ACCOMMODATING 50 FILMS ASSORTED SIZES HAND
~2: FEED; COMBINATION ADAPTER,AUTOMATIC ADAPTER,OR SINGLE FEED ADAPTER; DAYLIGHT INSTALLATION KIT

652500C959125

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127371

NSN

6525-01-012-7371

View More Info

652500C959125

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127371

NSN

6525-01-012-7371

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959125
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 10.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S29939

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127371

NSN

6525-01-012-7371

View More Info

S29939

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127371

NSN

6525-01-012-7371

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959125
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 10.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500C959130

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127372

NSN

6525-01-012-7372

View More Info

652500C959130

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127372

NSN

6525-01-012-7372

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959130
FEATURES PROVIDED: GRID CONTROL
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 270.0
TARGET ANGLE IN DEG: 270.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S30043

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127372

NSN

6525-01-012-7372

View More Info

S30043

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127372

NSN

6525-01-012-7372

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959130
FEATURES PROVIDED: GRID CONTROL
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 270.0
TARGET ANGLE IN DEG: 270.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500C959135

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127373

NSN

6525-01-012-7373

View More Info

652500C959135

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127373

NSN

6525-01-012-7373

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959135
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 10.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S30142

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127373

NSN

6525-01-012-7373

View More Info

S30142

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127373

NSN

6525-01-012-7373

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959135
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 180.0
TARGET ANGLE IN DEG: 10.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500C959137

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127374

NSN

6525-01-012-7374

View More Info

652500C959137

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127374

NSN

6525-01-012-7374

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959137
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 10.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S30139

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127374

NSN

6525-01-012-7374

View More Info

S30139

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127374

NSN

6525-01-012-7374

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959137
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.3 MM SQ; 1.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.3;1.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 10.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: STANDARD SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500C959046

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127375

NSN

6525-01-012-7375

View More Info

652500C959046

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127375

NSN

6525-01-012-7375

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959046
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.6;2.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S29239

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127375

NSN

6525-01-012-7375

View More Info

S29239

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127375

NSN

6525-01-012-7375

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959046
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 2.0 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MEDICAL X-RAY APPARATUS FOCAL SPOT SIZE 0.6;2.0MM SQ
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 15.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500C959047

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127376

NSN

6525-01-012-7376

View More Info

652500C959047

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127376

NSN

6525-01-012-7376

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959047
FEATURES PROVIDED: GRID CONTROL
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 1.2 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MED X-RAY APPAR HI-SPEED TUNGSTEN-RHENIUM 150KILOVOLT
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 12.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

S25227

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127376

NSN

6525-01-012-7376

View More Info

S25227

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127376

NSN

6525-01-012-7376

MFG

RAYTHEON CO MACHLETT LABORATORIES INC MW AND PT DIV

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959047
FEATURES PROVIDED: GRID CONTROL
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 1.2 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MED X-RAY APPAR HI-SPEED TUNGSTEN-RHENIUM 150KILOVOLT
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 12.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS

652500C959052

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127377

NSN

6525-01-012-7377

View More Info

652500C959052

TUBE UNIT,MEDICAL X-RAY APPARATUS

NSN, MFG P/N

6525010127377

NSN

6525-01-012-7377

MFG

ARMY MEDICAL SERVICE C/O THE SURGEON GENERAL DEPT OF THE ARMY ATTN MEDDD-SC

Description

ANODE HEAT CAPACITY RATING IN HEAT UNITS: 300000
CONTAINER TYPE: ANY ACCEPTABLE
DESIGN CONTROL REFERENCE: 652500C959052
FOCAL SPOT QUANTITY: 2
FOCAL SPOT SIZE: 0.6 MM SQ; 1.2 MM SQ
HOUSING X-RAY PROTECTIVE VALUE: X-RAY PROTECTIVE VALUE OF HOUSING SHALL BE IN ACCORDANCE WITH DHEW PUBLICATION NO. FDA 75-8003 JUL 1974
III PART NAME ASSIGNED BY CONTROLLING AGENCY: TUBE UNIT MED X-RAY APPAR HI-SPEED TUNGSTEN-RHENIUM 150KILOVOLT
MANUFACTURERS CODE: 81923
PORT TO CABLE RECEPTACLE ANGLE IN DEG: 0.0
TARGET ANGLE IN DEG: 12.0
TARGET BASE MATERIAL: MOLYBDENUM
TARGET FACE MATERIAL: TUNGSTEN-RHENIUM ALLOY
THE MANUFACTURERS DATA:
TUBE INSERT ANODE TYPE: HIGH SPEED ROTATING
TUBE INSERT FLUOROSCOPIC PEAK VOLTAGE RATING: NOT RATED
TUBE INSERT RADIOGRAPHIC PEAK VOLTAGE RATING: 150.0 KILOVOLTS