M8805-99-011
SWITCH,PUSH
NSN, MFG P/N
5930006219954
NSN
5930-00-621-9954
MFG
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR COLOR: BLACK SINGLE ACTUATOR
ACTUATOR DIAMETER: 0.350 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
ACTUATOR HEIGHT: 0.378 INCHES MINIMUM AND 0.438 INCHES MAXIMUM
BODY DIAMETER: 0.590 INCHES MINIMUM AND 0.650 INCHES MAXIMUM
BODY LENGTH: 1.000 INCHES MAXIMUM
BODY STYLE: 5K BUSHING MOUNTED
BUSHING LENGTH: 0.410 INCHES MINIMUM AND 0.470 INCHES MAXIMUM
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 3.000 AMPERES RESISTIVE DC AND 1.500 AMPERES INDUCTIVE DC AND 1.000 AMPERES LAMP DC AND 3.000 AMPERES RESISTIVE AC AND 1.500 AMPERES INDUCTIVE AC AND 1.000 AMPERES LAMP AC
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M8805/99-011
FEATURES PROVIDED: ACTUATOR SEAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WATERTIGHT
INCLOSURE TYPE: FULLY INCLOSED
MANUFACTURERS CODE: 81349
MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MOUNTING METHOD: THREADED BUSHING
NOMINAL THREAD SIZE: 0.469 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-8805/99
NONPILE
Related Searches:
M8805-99-012
SWITCH,PUSH
NSN, MFG P/N
5930006219954
NSN
5930-00-621-9954
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR COLOR: BLACK SINGLE ACTUATOR
ACTUATOR DIAMETER: 0.350 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
ACTUATOR HEIGHT: 0.378 INCHES MINIMUM AND 0.438 INCHES MAXIMUM
BODY DIAMETER: 0.590 INCHES MINIMUM AND 0.650 INCHES MAXIMUM
BODY LENGTH: 1.000 INCHES MAXIMUM
BODY STYLE: 5K BUSHING MOUNTED
BUSHING LENGTH: 0.410 INCHES MINIMUM AND 0.470 INCHES MAXIMUM
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 3.000 AMPERES RESISTIVE DC AND 1.500 AMPERES INDUCTIVE DC AND 1.000 AMPERES LAMP DC AND 3.000 AMPERES RESISTIVE AC AND 1.500 AMPERES INDUCTIVE AC AND 1.000 AMPERES LAMP AC
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M8805/99-011
FEATURES PROVIDED: ACTUATOR SEAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WATERTIGHT
INCLOSURE TYPE: FULLY INCLOSED
MANUFACTURERS CODE: 81349
MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MOUNTING METHOD: THREADED BUSHING
NOMINAL THREAD SIZE: 0.469 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-8805/99
NONPILE
Related Searches:
M8805/99-011
SWITCH,PUSH
NSN, MFG P/N
5930006219954
NSN
5930-00-621-9954
MFG
LOCKHEED MARTIN UK INSYS LTD
Description
ACTUATOR COLOR: BLACK SINGLE ACTUATOR
ACTUATOR DIAMETER: 0.350 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
ACTUATOR HEIGHT: 0.378 INCHES MINIMUM AND 0.438 INCHES MAXIMUM
BODY DIAMETER: 0.590 INCHES MINIMUM AND 0.650 INCHES MAXIMUM
BODY LENGTH: 1.000 INCHES MAXIMUM
BODY STYLE: 5K BUSHING MOUNTED
BUSHING LENGTH: 0.410 INCHES MINIMUM AND 0.470 INCHES MAXIMUM
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 3.000 AMPERES RESISTIVE DC AND 1.500 AMPERES INDUCTIVE DC AND 1.000 AMPERES LAMP DC AND 3.000 AMPERES RESISTIVE AC AND 1.500 AMPERES INDUCTIVE AC AND 1.000 AMPERES LAMP AC
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M8805/99-011
FEATURES PROVIDED: ACTUATOR SEAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WATERTIGHT
INCLOSURE TYPE: FULLY INCLOSED
MANUFACTURERS CODE: 81349
MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MOUNTING METHOD: THREADED BUSHING
NOMINAL THREAD SIZE: 0.469 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-8805/99
NONPILE
Related Searches:
10AT15-01
SWITCH,SENSITIVE
NSN, MFG P/N
5930006219956
NSN
5930-00-621-9956
MFG
SENSATA TECHNOLOGIES INC
Description
ACTUATOR DIAMETER: 0.065 INCHES MINIMUM AND 0.075 INCHES MAXIMUM
ACTUATOR FREE POSITION HEIGHT: 0.326 INCHES MINIMUM AND 0.346 INCHES MAXIMUM
ACTUATOR HEIGHT: 0.018 INCHES MINIMUM AND 0.038 INCHES MAXIMUM
ACTUATOR MOVEMENT: 0.009 PRETRAVEL INCHES MAXIMUM AND 0.003 OVERTRAVEL INCHES MINIMUM AND 0.005 DIFFERENTIAL INCHES MAXIMUM
ACTUATOR STYLE: 2 ROUND
BODY DIAMETER: 0.349 INCHES MINIMUM AND 0.379 INCHES MAXIMUM
BODY LENGTH: 0.335 INCHES MINIMUM AND 0.365 INCHES MAXIMUM
BODY STYLE: 6M HOLE MOUNTED
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 7.000 AMPERES RESISTIVE DC AND 3.000 AMPERES INDUCTIVE DC AND 2.000 AMPERES LAMP DC AND 5.000 AMPERES RESISTIVE AC AND 3.000 AMPERES INDUCTIVE AC AND 2.000 AMPERES LAMP AC
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M8805/68-005
FEATURES PROVIDED: ACTUATOR SEAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WEATHERPROOF
INCLOSURE TYPE: FULLY INCLOSED
MANUFACTURERS CODE: 81349
MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0
Related Searches:
M8805/68-005
SWITCH,SENSITIVE
NSN, MFG P/N
5930006219956
NSN
5930-00-621-9956
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR DIAMETER: 0.065 INCHES MINIMUM AND 0.075 INCHES MAXIMUM
ACTUATOR FREE POSITION HEIGHT: 0.326 INCHES MINIMUM AND 0.346 INCHES MAXIMUM
ACTUATOR HEIGHT: 0.018 INCHES MINIMUM AND 0.038 INCHES MAXIMUM
ACTUATOR MOVEMENT: 0.009 PRETRAVEL INCHES MAXIMUM AND 0.003 OVERTRAVEL INCHES MINIMUM AND 0.005 DIFFERENTIAL INCHES MAXIMUM
ACTUATOR STYLE: 2 ROUND
BODY DIAMETER: 0.349 INCHES MINIMUM AND 0.379 INCHES MAXIMUM
BODY LENGTH: 0.335 INCHES MINIMUM AND 0.365 INCHES MAXIMUM
BODY STYLE: 6M HOLE MOUNTED
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 7.000 AMPERES RESISTIVE DC AND 3.000 AMPERES INDUCTIVE DC AND 2.000 AMPERES LAMP DC AND 5.000 AMPERES RESISTIVE AC AND 3.000 AMPERES INDUCTIVE AC AND 2.000 AMPERES LAMP AC
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M8805/68-005
FEATURES PROVIDED: ACTUATOR SEAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WEATHERPROOF
INCLOSURE TYPE: FULLY INCLOSED
MANUFACTURERS CODE: 81349
MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0
Related Searches:
53HS15-04-1-24S
SWITCH,ROTARY
NSN, MFG P/N
5930006219965
NSN
5930-00-621-9965
MFG
GRAYHILL INC
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: MAKES BEFORE BREAKS EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0433
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 180.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 4
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REF
Related Searches:
M3786/36-0433
SWITCH,ROTARY
NSN, MFG P/N
5930006219965
NSN
5930-00-621-9965
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: MAKES BEFORE BREAKS EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0433
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 180.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 4
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REF
Related Searches:
396166-2
SWITCH,ROTARY
NSN, MFG P/N
5930006219980
NSN
5930-00-621-9980
MFG
EDO CORP DIV EDO CORPORATION ANTENNA PRODUCTS & TECHNOLOGIES
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0016
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 187.5 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 1
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
53HS15-01-1-17N
SWITCH,ROTARY
NSN, MFG P/N
5930006219980
NSN
5930-00-621-9980
MFG
GRAYHILL INC
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0016
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 187.5 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 1
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
M3786/36-0016
SWITCH,ROTARY
NSN, MFG P/N
5930006219980
NSN
5930-00-621-9980
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0016
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 187.5 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 1
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
M8805/96-012
SWITCH,PUSH
NSN, MFG P/N
5930006219981
NSN
5930-00-621-9981
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR COLOR: BLACK SINGLE ACTUATOR
ACTUATOR DIAMETER: 0.141 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
ACTUATOR HEIGHT: 0.121 INCHES MINIMUM AND 0.151 INCHES MAXIMUM
BODY DIAMETER: 0.328 INCHES MINIMUM AND 0.358 INCHES MAXIMUM
BODY STYLE: 5K BUSHING MOUNTED
BUSHING LENGTH: 0.267 INCHES MINIMUM AND 0.297 INCHES MAXIMUM
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 5.000 AMPERES RESISTIVE DC AND 2.000 AMPERES INDUCTIVE DC AND 5.000 AMPERES RESISTIVE AC AND 2.000 AMPERES INDUCTIVE AC
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M8805/96-012
FEATURES PROVIDED: ACTUATOR SEAL
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: WATERPROOF
INCLOSURE TYPE: FULLY INCLOSED
MANUFACTURERS CODE: 81349
MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MOUNTING METHOD: THREADED BUSHING
NOMINAL THREAD SIZE: 0.250 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-S-8805/96
NONPILE-UP CONTACT ARRANGEMENT: 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACT
Related Searches:
53HS15-02-1-24N
SWITCH,ROTARY
NSN, MFG P/N
5930006219982
NSN
5930-00-621-9982
MFG
GRAYHILL INC
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0076
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 187.5 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 2
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFEREN
Related Searches:
M3786/36-0076
SWITCH,ROTARY
NSN, MFG P/N
5930006219982
NSN
5930-00-621-9982
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0076
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 187.5 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 2
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFEREN
Related Searches:
57HS22-02-1-16NC
SWITCH,ROTARY
NSN, MFG P/N
5930006219983
NSN
5930-00-621-9983
MFG
GRAYHILL INC
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0901
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 2
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
921936-1
SWITCH,ROTARY
NSN, MFG P/N
5930006219983
NSN
5930-00-621-9983
MFG
NORTHROP GRUMMAN GUIDANCE AND ELECTRONICS COMPANY INC. DBA NAVIGATION SYSTEMS DIVISION DIV NAVIGATION SYSTEMS DIVISION
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0901
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 2
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
M3786-36-0901
SWITCH,ROTARY
NSN, MFG P/N
5930006219983
NSN
5930-00-621-9983
MFG
LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN SIMULATION TRAINING & SUPPORT
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0901
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 2
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
M3786/36-0901
SWITCH,ROTARY
NSN, MFG P/N
5930006219983
NSN
5930-00-621-9983
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES SINGLE SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0901
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 2
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFER
Related Searches:
37662296-020
SWITCH,ROTARY
NSN, MFG P/N
5930006219984
NSN
5930-00-621-9984
MFG
RAYTHEON CO
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0953
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 4
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFEREN
Related Searches:
57HS2204-1-16N-C
SWITCH,ROTARY
NSN, MFG P/N
5930006219984
NSN
5930-00-621-9984
MFG
GRAYHILL INC
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0953
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 4
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFEREN
Related Searches:
M3786/36
SWITCH,ROTARY
NSN, MFG P/N
5930006219984
NSN
5930-00-621-9984
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
CONTACT LOAD CURRENT RATING: 25.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL 75.0 MILLIAMPERES RESISTIVE LOAD AND 25.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CONTACT SWITCHING ACTION: BREAKS BEFORE MAKES EACH SECTION REAR
CONTACT VOLTAGE RATING IN VOLTS: 115.0 AC AT SEA LEVEL 28.0 DC AT SEA LEVEL
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M3786/36-0953
FIRST FLAT LENGTH: 0.250 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT: 0.216 INCHES NOMINAL SINGLE ACTUATOR
III DETENT ROTATIONAL TORQUE RANGE: 0.500 TO 2.500 INCH-POUNDS SINGLE ACTUATOR
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION: EXPLOSION PROOF
III OPERATING TEMP RANGE: -65.0 TO 125.0 DEG CELSIUS
III SHAFT FLAT/SLOT ANGULAR LOCATION: 191.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
INDIVIDUAL SECTION QUANTITY: 4
MANUFACTURERS CODE: 81349
MOUNTING METHOD: THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE: 0.375 INCHES SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFEREN