5945-01-118-1341
20 Products
0N275152
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181341
NSN
5945-01-118-1341
MFG
NATIONAL SECURITY AGENCY
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/24-018P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: POLARIZED AND COIL VOLTAGE SUPPRESSION
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/24
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: ESTABLISHED RELIABILITY; FAILURE RATE 0.1
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/24 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUA
Related Searches:
1064347-1
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011180916
NSN
5945-01-118-0916
MFG
RAYTHEON TECHNICAL SERVICES COMPANY LLC DBA RAYTHEON
Description
COIL QUANTITY: 2
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FREQUENCY IN HERTZ: 60.0 MINIMUM AND 400.0 MAXIMUM
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 2.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MANUFACTURERS CODE: 3B150
MFR SOURCE CONTROLLING REFERENCE: 1064347-1
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 12.7 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
OVERALL HEIGHT: 0.410 INCHES MAXIMUM
OVERALL LENGTH: 0.810 INCHES MAXIMUM
OVERALL WIDTH: 0.410 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
WINDING DC RESISTANCE RATING: 1.8 KILOHMS NOMINAL ALL WINDINGS
WINDING QUANTITY: 2
Related Searches:
55GB2100N1A1-8K2
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011180916
NSN
5945-01-118-0916
55GB2100N1A1-8K2
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011180916
NSN
5945-01-118-0916
MFG
ELECTRONIC SPECIALTY CORP RELAY DIV
Description
COIL QUANTITY: 2
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FREQUENCY IN HERTZ: 60.0 MINIMUM AND 400.0 MAXIMUM
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 2.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MANUFACTURERS CODE: 3B150
MFR SOURCE CONTROLLING REFERENCE: 1064347-1
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 12.7 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
OVERALL HEIGHT: 0.410 INCHES MAXIMUM
OVERALL LENGTH: 0.810 INCHES MAXIMUM
OVERALL WIDTH: 0.410 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 8 PIN ALL FUNCTIONS
WINDING DC RESISTANCE RATING: 1.8 KILOHMS NOMINAL ALL WINDINGS
WINDING QUANTITY: 2
Related Searches:
1115549
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181159
NSN
5945-01-118-1159
MFG
GENERAL MOTORS CORP DELCO REMY DIV
Description
RELAY,ELECTROMAGNETIC
Related Searches:
1115578
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181159
NSN
5945-01-118-1159
MFG
REMY INC.
Description
RELAY,ELECTROMAGNETIC
Related Searches:
490991
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181159
NSN
5945-01-118-1159
MFG
DRESSER INC. DIV DRESSER WAUKESHA
Description
RELAY,ELECTROMAGNETIC
Related Searches:
4911845
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181159
NSN
5945-01-118-1159
MFG
KALMAR AC INC
Description
RELAY,ELECTROMAGNETIC
Related Searches:
M39016/9-051P
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181333
NSN
5945-01-118-1333
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/9-051P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/9
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL HEIGHT: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT; LEAD LG 1.500 IN. MINIMUM
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/9 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 8 WIRE LE
Related Searches:
81349M39016/7-01
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181335
NSN
5945-01-118-1335
81349M39016/7-01
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181335
NSN
5945-01-118-1335
MFG
MAKINA VE KIMYA ENDUSTRISI KURUMU
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/7-013P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/7
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/7 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 5 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT: 81349-MIL-R-39016 SP
Related Searches:
M39016-7-001L
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181335
NSN
5945-01-118-1335
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/7-013P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/7
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/7 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 5 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT: 81349-MIL-R-39016 SP
Related Searches:
M1LR39016-39
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181337
NSN
5945-01-118-1337
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH: 1.200 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH: 0.400 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY: 1
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/39-006M
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 250.0 MILLIAMPERES AC AND 250.0 MILLIAMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 115.0 AC AND 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY PATTERN: RECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILR39016-39
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT: 0.997 INCHES NOMINAL
OVERALL LENGTH: 1.415 INCHES MAXIMUM
OVERALL WIDTH: 0.660
Related Searches:
M1L-R-3916/10
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181338
NSN
5945-01-118-1338
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/10-023P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/10
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.375 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT; LEAD LG 1.500 IN. MINIMUM
SPECIFICATION/STANDARD
Related Searches:
M39016/24-017P
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181339
NSN
5945-01-118-1339
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/24-017P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: POLARIZED AND COIL VOLTAGE SUPPRESSION
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/24
NONPILE-UP MAIN CONTACT ARRANGEMENT: 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 18.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: ESTABLISHED RELIABILITY
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/20 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY: 8 WIRE LEAD
Related Searches:
230598-000
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181340
NSN
5945-01-118-1340
MFG
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/23-014P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: COIL VOLTAGE SUPPRESSION AND POLARIZED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/23
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL HEIGHT: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/23 GOVERNMENT SPECIFICATION
T
Related Searches:
411D2124
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181340
NSN
5945-01-118-1340
MFG
TELEDYNE RELAYS TELEDYNE INDUSTRIES INC SUB OF TELEDYNE INC
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/23-014P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: COIL VOLTAGE SUPPRESSION AND POLARIZED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/23
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL HEIGHT: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/23 GOVERNMENT SPECIFICATION
T
Related Searches:
J1MAWD-6M
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181340
NSN
5945-01-118-1340
MFG
HI-G CO INC SUB OF NYTRONICS INC
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/23-014P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: COIL VOLTAGE SUPPRESSION AND POLARIZED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/23
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL HEIGHT: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/23 GOVERNMENT SPECIFICATION
T
Related Searches:
M39016/23-002M
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181340
NSN
5945-01-118-1340
MFG
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/23-014P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: COIL VOLTAGE SUPPRESSION AND POLARIZED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/23
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL HEIGHT: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: FAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/23 GOVERNMENT SPECIFICATION
T
Related Searches:
1150666-2
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181341
NSN
5945-01-118-1341
MFG
U S ARMY AVIATION AND MISSILE COMMAND
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/24-018P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: POLARIZED AND COIL VOLTAGE SUPPRESSION
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/24
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: ESTABLISHED RELIABILITY; FAILURE RATE 0.1
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/24 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUA
Related Searches:
2387298-1
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181341
NSN
5945-01-118-1341
MFG
LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/24-018P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: POLARIZED AND COIL VOLTAGE SUPPRESSION
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/24
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: ESTABLISHED RELIABILITY; FAILURE RATE 0.1
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/24 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUA
Related Searches:
411DD26
RELAY,ELECTROMAGNETIC
NSN, MFG P/N
5945011181341
NSN
5945-01-118-1341
MFG
TELEDYNE RELAYS TELEDYNE INDUSTRIES INC SUB OF TELEDYNE INC
Description
COIL QUANTITY: 1
CRITICALITY CODE JUSTIFICATION: FEAT
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: M39016/24-018P
DUTY TYPE: CONTINUOUS
ENVIRONMENTAL PROTECTION: HERMETIC
FEATURES PROVIDED: POLARIZED AND COIL VOLTAGE SUPPRESSION
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE: 1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS: 28.0 DC
MANUFACTURERS CODE: 81349
MOUNTING FACILITY TYPE AND QUANTITY: 1 TERMINAL SINGLE MOUNTING FACILITY
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MIL-PRF-39016/24
NONPILE-UP MAIN CONTACT ARRANGEMENT: 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP: 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER: 0.370 INCHES MAXIMUM
OVERALL LENGTH: 0.280 INCHES MAXIMUM
SPEC/STD CONTROLLING DATA:
SPECIAL FEATURES: ESTABLISHED RELIABILITY; FAILURE RATE 0.1
SPECIFICATION/STANDARD DATA: 81349-MIL-R-39016/24 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUA