PAM1510-50-250-60

CIRCUIT BREAKER

NSN, MFG P/N

5925002705899

NSN

5925-00-270-5899

View More Info

PAM1510-50-250-60

CIRCUIT BREAKER

NSN, MFG P/N

5925002705899

NSN

5925-00-270-5899

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 3.709 INCHES MINIMUM AND 3.729 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.980 INCHES MINIMUM AND 1.000 INCHES MAXIMUM
BOSS HEIGHT: 0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 3.053 INCHES MINIMUM AND 3.073 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT: 4.250 OUNCES
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FRE

AM12-15M6

CIRCUIT BREAKER

NSN, MFG P/N

5925002705912

NSN

5925-00-270-5912

View More Info

AM12-15M6

CIRCUIT BREAKER

NSN, MFG P/N

5925002705912

NSN

5925-00-270-5912

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: FUNGUS RESISTANT
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RAT

AM12-25M6

CIRCUIT BREAKER

NSN, MFG P/N

5925002705914

NSN

5925-00-270-5914

View More Info

AM12-25M6

CIRCUIT BREAKER

NSN, MFG P/N

5925002705914

NSN

5925-00-270-5914

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 2.500 INCHES NOMINAL
BODY STYLE: 12A SINGLE POLE TYPE
BODY WIDTH: 0.750 INCHES NOMINAL
BOSS HEIGHT: 0.140 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.938 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.062 INCHES NOMINAL
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF AND FUNGUS PROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 25.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAP

1213P15

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

1213P15

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION CODE 4.8.8.0.0.B BLDG 148-2

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

1215

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

1215

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

21-1080809

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

21-1080809

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

64

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

64

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

EATON CORPORATION DBA FLUID POWER DIV DIV POWER AND LOAD MANAGEMENT SYSTEMS USE CAGE CODE 81640 FOR CATALOGING.

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

9311-15A

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

9311-15A

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

SCHNEIDER ELECTRIC USA INC.

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

AN3161P15

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

AN3161P15

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

D6751-2-15

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

View More Info

D6751-2-15

CIRCUIT BREAKER

NSN, MFG P/N

5925002705924

NSN

5925-00-270-5924

MFG

SENSATA TECHNOLOGIES INC

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
MANUFACTURERS CODE: 81349
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 15.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 2 THREADED HOLE
NOMINAL THREAD SIZE: 0.138 INCHES
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE: MILC7079
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 30.0 DC SINGLE LOCATION
OVERALL HEIGHT: 2.625 INCHES NOMINAL
OVERALL LENGTH: 2.188 INCHES NOMINAL
POLE QUANTITY: 1
RESET METHOD: AUTOMATIC
SPEC/STD CONTROLLING DATA:
TERMINAL TYPE AND QUANTITY: 2 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 10.000 MINIMUM AT 200 PCT SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION

2263-10-115-2

CIRCUIT BREAKER

NSN, MFG P/N

5925002705944

NSN

5925-00-270-5944

View More Info

2263-10-115-2

CIRCUIT BREAKER

NSN, MFG P/N

5925002705944

NSN

5925-00-270-5944

MFG

EATON CORP AEROSPACE COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLO

687596

CIRCUIT BREAKER

NSN, MFG P/N

5925002705944

NSN

5925-00-270-5944

View More Info

687596

CIRCUIT BREAKER

NSN, MFG P/N

5925002705944

NSN

5925-00-270-5944

MFG

NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLO

2263SM6-10

CIRCUIT BREAKER

NSN, MFG P/N

5925002705945

NSN

5925-00-270-5945

View More Info

2263SM6-10

CIRCUIT BREAKER

NSN, MFG P/N

5925002705945

NSN

5925-00-270-5945

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLO

2263SM6-10-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002705945

NSN

5925-00-270-5945

View More Info

2263SM6-10-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002705945

NSN

5925-00-270-5945

MFG

KLEINSCHMIDT INC

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLO

260-4283-40

CIRCUIT BREAKER

NSN, MFG P/N

5925002705947

NSN

5925-00-270-5947

View More Info

260-4283-40

CIRCUIT BREAKER

NSN, MFG P/N

5925002705947

NSN

5925-00-270-5947

MFG

ROCKWELL COLLINS INC. DBA GOVERNMENT SYSTEMS DIV GOVERNMENT SYSTEMS

Description

CASE MATERIAL: PLASTIC
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III SPECIAL HANDLING FEATURE: MAGNETIC
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 10.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 3000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 THREADED HOLE
NOMINAL THREAD SIZE: 0.164 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
POLE QUANTITY: 2
RESET METHOD: MANUAL
TERMINAL TYPE AND QUANTITY: 4 SCREW
THREAD QUANTITY PER INCH: 32
THREAD SERIES DESIGNATOR: UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 40.000 MINIMUM AT 200 PCT AND

2263M6-40-19

CIRCUIT BREAKER

NSN, MFG P/N

5925002705954

NSN

5925-00-270-5954

View More Info

2263M6-40-19

CIRCUIT BREAKER

NSN, MFG P/N

5925002705954

NSN

5925-00-270-5954

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLO

3363S-25-250-60-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002705963

NSN

5925-00-270-5963

View More Info

3363S-25-250-60-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002705963

NSN

5925-00-270-5963

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 11B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III

3363SMG4-6-250-60-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002705967

NSN

5925-00-270-5967

View More Info

3363SMG4-6-250-60-3

CIRCUIT BREAKER

NSN, MFG P/N

5925002705967

NSN

5925-00-270-5967

MFG

EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV

Description

ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY HEIGHT: 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
BODY LENGTH: 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
BODY STYLE: 9B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
BOSS HEIGHT: 0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 3.052 INCHES MINIMUM AND 3.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III F

G2040T

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002705982

NSN

5925-00-270-5982

View More Info

G2040T

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002705982

NSN

5925-00-270-5982

MFG

WESTINGHOUSE ELECTRIC CORP

Description

ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 250.0 TO 500.0 AC AND 250.0 TO 500.0 DC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 40.0 AMPERES AC AND 40.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 3.562 INCHES NOMINAL
OVERALL LENGTH: 5.000 INCHES NOMINAL
OVERALL WIDTH: 4.312 INCHES NOMINAL
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 92.000 MINIMUM AT 200 PCT AND 250.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHA

K2175T

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002705986

NSN

5925-00-270-5986

View More Info

K2175T

TRIPPER,CIRCUIT BREAKER

NSN, MFG P/N

5925002705986

NSN

5925-00-270-5986

MFG

EATON CORPORATION

Description

ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS: 500.0 TO 1750.0 AC AND 500.0 TO 1750.0 DC ALL LOCATIONS
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FEATURES PROVIDED: ADJUSTABLE TRIP RELEASE
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 175.0 AMPERES AC AND 175.0 AMPERES DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 TERMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC AND 250.0 DC ALL LOCATIONS
OVERALL HEIGHT: 3.250 INCHES NOMINAL
OVERALL LENGTH: 4.750 INCHES NOMINAL
OVERALL WIDTH: 3.750 INCHES NOMINAL
POLE QUANTITY: 2
TERMINAL TYPE AND QUANTITY: 4 COMPRESSION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT: 108.000 MINIMUM AT 200 PCT AND 500.000 MAXIMUM AT 200 PCT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING: 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEAS