307A8774P1
CIRCUIT BREAKER
NSN, MFG P/N
5925011962083
NSN
5925-01-196-2083
MFG
BAE SYSTEMS CONTROLS INC.
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
AUXILIARY SWITCH FUNCTION AND QUANTITY: 1 ALARM
BODY LENGTH: 1.562 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.937 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.900 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.625 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: HERMETICALLY SEALED
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 2.5 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 300.
Related Searches:
JE1S-T3-A-0015-02E
CIRCUIT BREAKER
NSN, MFG P/N
5925011952302
NSN
5925-01-195-2302
MFG
EATON CORP AEROSPACE COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM
BODY STYLE: 2A SINGLE POLE TYPE
BODY WIDTH: 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
BUSHING LENGTH: 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.529 INCHES MINIMUM AND 1.591 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
CRITICALITY CODE JUSTIFICATION: FEAT
FREQUENCY IN HERTZ: 50.0 OR 60.0 SINGLE LOCATION
III ARC QUENCHING METHOD: MAGNETIC BLOWOUT
III END ITEM IDENTIFICATION: USNS STALWART CLASS TAGOS, POWHATAN CLASS T-ATF 166; AVENGER CLASS MCM
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: DUSTPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TY
Related Searches:
IUGH666-1-42-20.0-Q-91
CIRCUIT BREAKER
NSN, MFG P/N
5925011952303
NSN
5925-01-195-2303
IUGH666-1-42-20.0-Q-91
CIRCUIT BREAKER
NSN, MFG P/N
5925011952303
NSN
5925-01-195-2303
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.245 INCHES MINIMUM AND 2.255 INCHES MAXIMUM
BOSS HEIGHT: 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWO
Related Searches:
JA3-W3-A-20-2
CIRCUIT BREAKER
NSN, MFG P/N
5925011952303
NSN
5925-01-195-2303
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.245 INCHES MINIMUM AND 2.255 INCHES MAXIMUM
BOSS HEIGHT: 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 400.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETIC BLOWO
Related Searches:
AS33201
CIRCUIT BREAKER
NSN, MFG P/N
5925011952304
NSN
5925-01-195-2304
MFG
SOCIETY OF AUTOMOTIVE ENGINEERS INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.781 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.593 INCHES MAXIMUM
BUSHING LENGTH: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.3
Related Searches:
MS3320-4V
CIRCUIT BREAKER
NSN, MFG P/N
5925011952304
NSN
5925-01-195-2304
MFG
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE ONE
BODY LENGTH: 0.781 INCHES MAXIMUM
BODY STYLE: 1A SINGLE POLE TYPE
BODY WIDTH: 0.593 INCHES MAXIMUM
BUSHING LENGTH: 0.250 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 0.500 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT SINGLE LOCATION
FREQUENCY IN HERTZ: 400.0 SINGLE LOCATION
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: VIBRATIONPROOF
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 PUSH-PULL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 4.0 AMPERES AC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 2500.0 AC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY: 1 THREADED BUSHING W/PANEL SEAL
MOUNTING SURFACE TO TERMINAL END DISTANCE: 1.3
Related Searches:
701363-711935
CIRCUIT BREAKER
NSN, MFG P/N
5925011952849
NSN
5925-01-195-2849
MFG
TILLEY MFG CO INC
Description
CIRCUIT BREAKER
Related Searches:
711935
CIRCUIT BREAKER
NSN, MFG P/N
5925011952849
NSN
5925-01-195-2849
MFG
SPD ELECTRICAL SYSTEMS INC
Description
CIRCUIT BREAKER
Related Searches:
706993SH1
CIRCUIT BREAKER
NSN, MFG P/N
5925011952985
NSN
5925-01-195-2985
MFG
SPD ELECTRICAL SYSTEMS INC
Description
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DESIGN CONTROL REFERENCE: 706993SH1
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
MANUFACTURERS CODE: 30086
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 500.0 AC ALL LOCATIONS
POLE QUANTITY: 3
THE MANUFACTURERS DATA:
Related Searches:
413-267
CIRCUIT BREAKER
NSN, MFG P/N
5925011953751
NSN
5925-01-195-3751
MFG
CAE INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.251 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETI
Related Searches:
AM3-A3-40-3
CIRCUIT BREAKER
NSN, MFG P/N
5925011953751
NSN
5925-01-195-3751
MFG
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT EACH POLE
BODY LENGTH: 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY STYLE: 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY WIDTH: 2.240 INCHES MINIMUM AND 2.251 INCHES MAXIMUM
BOSS HEIGHT: 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH: 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH: 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH: 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT: ONE, TWO, AND THREE LINKED
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: MAGNETI
Related Searches:
TJK636T450
TRIPPER,CIRCUIT BREAKER
NSN, MFG P/N
5925011957258
NSN
5925-01-195-7258
MFG
GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: AT POLE TWO
BODY STYLE: 1D RECTANGULAR DIMENSIONAL ENVELOPE
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 450.0 AMPERES AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 UNTHREADED HOLE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 600.0 AC ALL LOCATIONS
OVERALL HEIGHT: 3.812 INCHES NOMINAL
OVERALL LENGTH: 10.125 INCHES NOMINAL
OVERALL WIDTH: 8.250 INCHES NOMINAL
POLE QUANTITY: 3
TERMINAL TYPE AND QUANTITY: 6 COMPRESSION
TRIP RELEASE AMBIENT TEMP RATING: 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC: INSTANTANEOUS ALL LOCATIONS
TRIP RELEASE METHOD: THERMAL-MAGNETIC ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PER
Related Searches:
TY-ALB-1/15A-1
CIRCUIT BREAKER
NSN, MFG P/N
5925011958068
NSN
5925-01-195-8068
MFG
NAVAL INVENTORY CONTROL POINT MECHANICSBURG
Description
CRITICALITY CODE JUSTIFICATION: ZZZY
DESIGN CONTROL REFERENCE: TY-ALB-1/15A-1
MANUFACTURERS CODE: 03950
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS: MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS
THE MANUFACTURERS DATA:
Related Searches:
203-11-6905-1
CIRCUIT BREAKER
NSN, MFG P/N
5925011961054
NSN
5925-01-196-1054
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 1.770 INCHES NOMINAL
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 20B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES NOMINAL
BOSS HEIGHT: 0.125 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.620 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
P
Related Searches:
5977324P1
CIRCUIT BREAKER
NSN, MFG P/N
5925011961054
NSN
5925-01-196-1054
MFG
CALCOMP INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY HEIGHT: 1.770 INCHES NOMINAL
BODY LENGTH: 2.000 INCHES NOMINAL
BODY STYLE: 20B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.320 INCHES NOMINAL
BOSS HEIGHT: 0.125 INCHES NOMINAL
CASE MATERIAL: PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.620 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 50.0 OR 60.0 ALL LOCATIONS
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY: 4 CLIP
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS: 250.0 AC ALL LOCATIONS
P
Related Searches:
41512CB
CIRCUIT BREAKER
NSN, MFG P/N
5925011961055
NSN
5925-01-196-1055
MFG
ELECTRONIC RESEARCH ASSOCIATES INC TRANSPAC POWER SUPPLY DIV
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY LENGTH: 1.500 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.250 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP FIRST LOCATION RELAY TRIP SECOND LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOU
Related Searches:
AP14-1060-2
CIRCUIT BREAKER
NSN, MFG P/N
5925011961055
NSN
5925-01-196-1055
MFG
SENSATA TECHNOLOGIES MARYLAND INC
Description
ACTUATOR FUNCTION: TRIP-RESET
ACTUATOR POSITION DESIGNATION: BETWEEN POLE ONE AND TWO
BODY LENGTH: 1.500 INCHES MAXIMUM
BODY STYLE: 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH: 1.250 INCHES MAXIMUM
BUSHING LENGTH: 0.380 INCHES MAXIMUM
CASE MATERIAL: METAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH: 0.375 INCHES NOMINAL
CIRCUIT PROTECTION TYPE: OVERCURRENT ALL LOCATIONS
FREQUENCY IN HERTZ: 60.0 ALL LOCATIONS
III ARC QUENCHING METHOD: AIR
III FRAGILITY FACTOR: MODERATELY RUGGED
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED: GENERAL PURPOSE
INTERNAL TRIP RELEASE CONFIGURATION: SERIES TRIP FIRST LOCATION RELAY TRIP SECOND LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY: 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE: 5.0 AMPERES AC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS: 1000.0 AC ALL LOCATIONS
MOU
Related Searches:
36-022F01M00
CIRCUIT BREAKER
NSN, MFG P/N
5925011961831
NSN
5925-01-196-1831
MFG
CONCURRENT COMPUTER CORPORATION
Description
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
RESET METHOD: MANUAL
Related Searches:
36-038F00M00
CIRCUIT BREAKER
NSN, MFG P/N
5925011961832
NSN
5925-01-196-1832
MFG
CONCURRENT COMPUTER CORPORATION
Description
III STORAGE TYPE: GENERAL PURPOSE WAREHOUSE
MAIN CONTACT TRIPPING MECHANISM TYPE: TRIP FREE
RESET METHOD: MANUAL
Related Searches:
KS2068413
CIRCUIT BREAKER
NSN, MFG P/N
5925011961996
NSN
5925-01-196-1996
MFG
LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP